| Imager: |
1/3
inch Interline type Progressive Scan CCD |
| Cell
Size: |
7.4
x 7.4 [square lattice] |
| Frame rate |
60 frames/second (full pixel readout) |
| Scanning frequency |
Horizontal: 31.468 kHz
Vertical: 60 Hz |
| Video output |
Digital output (CameraLink)
Data : Base configuration 10bit or 8bit x 1
CLK=24.5454MHz |
| Electronic shutter speed |
1/60, 1/250, 1/500, 1/1000, 1/2000, 1/4000 |
| |
factory setting is off (1/60 second) or variable shutter (minimum 1/100000 seconds) |
| Frame on demand |
(Remote setting (fixed shutter, one trigger, and reset control mode) Factory setting is all off. |
| Ambient temperature |
| Operation |
0 to + 40 ºC (+32 to ; 104 ºF), less than 90 % RH |
| Storage |
-10 to + 50 ºC (+14 to +122 ºF), less than 70 % RH |
* If operated continuously, be sure to use at less than +40 ºC (104 ºF) for
long term stable performance. |
|
| Vibration endurance |
98 m/s2 (10 to 60Hz, amplitude: 0.98mm constant / 60 to 200Hz, amplitude: variable)
(10 to 150Hz, sweep:1 min, XYZ, 30 min) |
| Shock endurance |
686 m/s2 (Drop test, once each top, bottom, left and right) |