The Industrial Camera and Machine Vision Solutions Company














Call us Toll Free
 
 
 
Home  |  General Information  |  Find a Rep  |  Trade Shows  |  Order  |  Contact  
 

National Instruments

NI PCI-1428 and NI PXI-1428
Base and Medium Configuration Camera Link image acquisition boards.
(View brochure in Adobe PDF)

NI PCI-1428 and NI PXI-1428 Base and Medium Configuration Camera Link image acquisition boards


For machine vision and scientific imaging applications that require high-resolution digital imaging with simple cabling, the National Instruments PCI-1428 and PXI-1428 are image acquisition devices for base- and medium-configuration Camera Link cameras. You can find a list of supported Camera Link cameras in the Camera Advisor.

  • Standard Camera Link cabling
  • 16 MB onboard memory
  • Base- and medium-configuration image acquisition for
        Camera Link cameras
  • 4 lookup tables, 256-by-8-bits
  • Onboard programmable region of interest
  • Pixel decimation and image scaling
  • Specifications
    Typical at 25° C, unless otherwise stated.

    External Connections
    Trigger sense TTL
    Trigger polarity Programmable (positive or negative)
    Pixel clock Camera Link compatible
    Enables Camera Link compatible
    Control signal Camera Link compatible
    Video data Camera Link compatible
    Clocks
    Pixel clock frequency range 20 to 50 MHz
    PCI Master Performance
    Sustained 100 MB/s
    Onboard Memory
    PCI 16 MB
    PXI 32 MB
    Power Requirements
    +5 VDC 1.5 A
    +12 VDC 24 mA
    -12 VDC 20 mA
    Physical Dimensions
    PCI 10.7 by 17.5 cm (4.2 by 6.9 in.)
    PXI 10 by 16 cm (3.9 by 6.3 in.)
    Environment
    Operating temperature 0 to 55 °C
    Storage temperature -20 to 70 °C
    Relative humidity 5 to 90%, noncondensing
    MTBF 544,562 h at 25 °C
    Emissions EN 55011:1991 Group 1 Class A
    at 10 m FCC Class A at 10 m